Do
you need an Arc Flash Study for NEC Compliance?
You
may ask why an Arc Flash study should be performed at your
location. Well actually one is not required by the National
Electrical Code (NEC), but we strongly suggest that you do
have one done. The NEC only requires that Arc Flash labels be
displayed to warn of potential electric Arc Flash hazards. If a
study has not been performed at your installation, then you are
missing out on a detailed study that includes the NEC required
Arc Flash labels and suggestions to reduce Arc Flash energy. We
go above and beyond the minimum NEC requirements and include
labels that display very important detailed information
such as Arc Flash Boundaries, level of PPE required with PPE
description, Arc Flash Energy, and other device specific
details.
Do
you need an Arc Flash Study for NFPA70E Compliance?
The
NFPA70E clearly states electrical equipment should not be worked
on while in an energized state. However, the equipment is
considered to be energized until verified it has been
de-energized. During the verification process the employee is
potentially exposed to energized electrical parts. This exposure
of the employee to energized parts places a requirement on the
employer to provide Personal Protection Equipment (PPE). The
NFPA70E outlines what type of PPE is required to be provided by
the employer. The employer has two options to determine the type
of PPE that complies with the NFPA70E:
1. NFPA70E, 2004, article 130.3
states, “A flash hazard analysis shall be done in order
to protect personnel from the possibility of being injured by an
arc flash.”
This option
requires the employer to provide either an independent
outside source or a qualified internal source to perform
this analysis in accordance with the calculations
defined by the NFPA70E or IEEE 1584. This option defines
what level of PPE is required.
2. NFPA70E, 2004, article 130.7(C-9)
“Selection of Personal Protective Equipment” states, “When PPE
is selected in lieu of flash hazard analysis, Table 130.7
(C-9a) shall be used to determine the hazard/risk
category for a task.”
This option
requires the employer and the employee to make the
determination of what level of PPE is required. This
option shall NOT be used if the system has a
short-circuit capacity or fault clearing times greater
than what the tables were designed for.
The NFPA70E requirements take into consideration that the
electrical system should have been installed and maintained in
accordance with the NEC. If the system has been improperly
maintained or has underrated equipment installed, it is a VIOLATION
of the NEC. Therefore, the guidelines provided by the NFPA70E
may not adequately protect your employees.
Personal Protective Equipment, “PPE”
PPE is used to limit the injury incurred
during a fault to a level no greater than the exposure
of bare skin to an open flame for approximately 1 second
(approx 1.2 cal/cm^2, a curable 2nd degree
burn). If an Arc Flash study has not been performed at
your installation, NFPA 70E has several tables that your
“qualified personnel” should apply when
determining PPE. In some cases the PPE worn by your
“qualified personnel” is oversized for a certain task in
a specific location. In other cases where improper
equipment is installed or existing equipment is
maintained improperly, the Arc Flash energy could be MUCH GREATER than what their
PPE can protect them from. If a fault has
an Arc Flash energy greater than 40 cal/cm^2 the
pressure wave will be so great that PPE can no longer
provide adequate protection. Our Arc Flash study
provides suggestions on how to reduce Arc Flash energy
to safer levels, and it also points out improperly
maintained and installed equipment.
How
to Reduce Arc Flash Energy
There are three ways that Arc Flash energy can be decreased.
First, the available short circuit current from the utility
could be decreased (probably not possible). Second, the
impedance in the local power distribution system could be
increased (may be difficult and/or expensive). Third, the trip
time of protective devices could be decreased. One of the more
common suggestions that we have made to reduce Arc Flash energy
is circuit breaker trip adjustment. The adjustment of circuit
breaker tripping devices can decrease the amount of Arc Flash
energy
that is the result of a fault. Care must be taken when
implementing this solution, as protective device coordination
may be affected when reducing the trip time of protective
devices. A benefit of decreasing the Arc Flash energy
is that it
could lower the level of PPE required.
Why
should we perform an Arc Flash Study for you?
An Arc Flash
study is not required by the NEC, but Arc Flash equipment
warning labels are. If you do not have any Arc Flash labels
now, you need to install them.
These
labels are included in our Arc Flash study.
An Arc Flash
study may be required by the NFPA70E.
If your
system falls outside the boundaries set for the NFPA70E
PPE tables, then an Arc Flash study is required.
We provide
calculated Arc Flash energy values and labels that will
be a key part of your Electrical Safety training.
If your
electrical personnel do not know what level of PPE is
required for a task, as per NFPA70E, you need to inform
them.
We inform
you of the
required
NFPA70E PPE
level and provide
a detailed Arc Flash label which can be placed on
equipment.
Do you have
improperly maintained or installed equipment that would
cause the increase of Arc Flash Energy or increase the
potential for a fault to occur?
Your
system will be
thoroughly
analyzed
as a part of the
Arc Flash
energy calculations.
The following are common areas of
concern:
-
Circuit breaker trip settings
-
Using Motor Circuit Protectors
“MCPs” as feeder breakers
-
Under-rated or improperly sized
fuses and circuit breakers
-
Under-rated Motor Control Center
“MCC” buss bracing
-
Under-rated MCC starters and feeder
breakers
-
Under-rated Switchgear,
Switchboards, and Panelboards
So,
why not let us give you a quote to perform a detailed study that
will include the required labels, required level of PPE details,
and suggestions on how to decrease the available Arc Flash
energy?
NIOSH (National Institute for Occupational Safety and Health)
Regarding Arc Flash
|
With
NIOSH approval, a
link to NIOSH’s Arc
Flash Training video
has been added to
our website. This
video is
approximately 26
minutes long, and
could be a valuable
tool to aid in
informing personnel
of the hazards of
Arc Flash.
|

click picture to go
to NIOSH training
videl |
|